Gas Service Access - Heat & Glo MEZZO-1000-AU Installation Manual

Hide thumbs Also See for MEZZO-1000-AU:
Table of Contents

Advertisement

C. Gas Service Access
This appliance does include a manual gas shutoff
Note:
valve that is located in the valve compartment. This manual
gas shutoff valve is accessible for service by removing the
decorative front and the vanity panel. The valve is most
accessible if it is located forward in the control cavity of the
appliance.
Depending upon local code, an additional manual gas
shutoff, in a readily accessible area may be required
and located upstream from the appliance.
The lower access cover panel is removable if finishing
material is not installed. See Figure 9.2.
Figure 9.2. Vanity Panel and Lower Access Panel Location
If the finishing materials have been installed around
the appliance opening, proceed as follows:
1. Remove vanity panel.
2. Remove screws on left and right sides of component
heat shield and lift it out of the control cavity.
CAUTION! Risk of Overheating! Component heat
shield MUST be installed before operating appliance.
Electrical components will be damaged.
3. Unplug the 6V transformer from the junction cord.
This will turn the power off to the appliance.
Heat & Glo • MEZZO-1000-AU, MEZZO-1300-AU, MEZZO-1300ST-AU, MEZZO-1600-AU Installation Manual • 2304-970 Rev. D • 3/15