Y
-
Drive Lower Layout
Y
-
Drive Lower Layout
Y-Drive
Y-SUS
This connector does not
come with a new
Y-SUS or Y-Drive.
P209
PANEL
SIDE
Warning: Never run the Y-SUS with just P209
disconnected. You must remove the Lower
Y-Drive board completely due to these FG lugs.
Y-Scan signal, FG5V from the Y-SUS board and
Logic Signals from the Control board through the
Y-SUS are supplied to the Lower Y-Drive Board
on Connector P209.
Y-SUS
SIDE
82
October 2010
p/n: EBR63461101
Floating
Ground
Standoff
The Floating Ground
Standoff delivers FG
To the Y-Drive Boards.