Download Print this page

LG 50PK950 Training Manual page 77

Hide thumbs Also See for 50PK950:

Advertisement

Y
-
SUS P101 to Control P1 Plug Voltage Checks
Y
-
SUS P101 to Control P1 Plug Voltage Checks
"Y-SUS" P101 Connector to "Control" P1
Pin
Label
Run
1
Error
13.57V
2
CTRL_EN
0.09V
3
n/c
n/c
4
Gnd
Gnd
5
CLK
0.384V
6
Gnd
Gnd
7
STB
2.87V
8
Gnd
Gnd
9
OC1_B
1.12V
10
OC1_T
1.13V
11
OC2_B
1.13V
12
OC2_T
1.13V
13
DATA_B
0V
14
DATA_T
0V
15
Gnd
Gnd
16
SUS_DN
2.46V
17
Gnd
Gnd
18
SUS_UP
0.12V
19
Gnd
Gnd
20
ER_DN
0.12V
21
Gnd
Gnd
22
ER_UP
1.14V
Diode
Pin
Label
Open
23
Gnd
3.17V
24
PASS
Open
25
SET_DN1
Gnd
26
SET_DN2
2.83V
27
SET_DN3
Gnd
28
Gnd
2.84V
29
SET_UP1
Gnd
30
SET_UP2
2.82V
31
D_VY_EN
2.83V
32
D_VY1
2.83V
33
GND
2.83V
34
D_VY2
2.82V
35
NC1
2.82V
36
NC2
Gnd
37
NC3
2.82V
38
GND
Gnd
39
GND
2.83V
40
n/c
Gnd
41-45
M5V
2.82V
46
n/c
Gnd
47-50
18V
2.83V
Run
Diode
Gnd
Gnd
2.03V
2.84V
2.12V
2.84V
2.12V
2.84V
2.36
2.83V
Gnd
Gnd
0.88V
2.82V
0V
2.82V
0.26V
3.0V
0V
2.83V
Gnd
Gnd
0.28V
2.82V
0.6V
2.84V
0V
3.0V
2.03V
2.82V
Gnd
Gnd
Gnd
Gnd
n/c
Open
4.92V
1.3V
n/c
n/c
18.3V
1.32V
77
October 2010
There are No Stand By
Voltages on this Connector
Diode Mode Readings
taken with all connectors
Disconnected.
DVM in Diode Mode.
50PK950
Plasma

Advertisement

loading