Power Supply Va and Vs Adjustments
Power Supply Va and Vs Adjustments
Important: Use the Panel Label
Not this book for all voltage adjustments.
Use Full White Raster "White Wash"
Va TP
P812
Pin 6 or 7
Vs TP
P812
Pin 1 or 2
Example
Voltage Label
Vs Adjust:
Place voltmeter on VS TP.
Adjust VR901 until the reading
matches your Panel's label.
Va Adjust:
Place voltmeter on VA TP.
Adjust VR501 until the reading
matches your Panel's label.
51
October 2010
Model : PDP 50R1###
Voltage Setting: 5V/ Va:60/ Vs:203
N.A. / -190 / 150 / N.A. / 115
Max Watt : 450 W (Full White)
VA
Voltage
50PK950
VS
Voltage
Plasma