Installation
iv. Measure the protrusion of the bolts of the coil
carrier sheet. The bolts must protrude 5mm from the
bottom of the coil carrier sheet.
v. Measure the distance between the underside of the
coil carrier sheet to the Ceran® glass. The distance
must be 50mm +/- 2mm.
vi. When you do not obtain the measurements in (i)
and (ii), insert screws (not provided, size M4) into
the threaded holes on the retaining rails. Tighten
or loosen the M4 screws until you get the correct
measurements.
See Electrical Installation on page 37 to connect the
components.