Annual Service And Start-Up - Weil-McLain ULTRA OIL Manual

Oil-fired water boiler
Hide thumbs Also See for ULTRA OIL:
Table of Contents

Advertisement

®
WATER BOILER

Annual service and start-up

The boiler should be inspected and started annually, at the
beginning of the heating season, only by a qualified service
technician. In addition, the maintenance and care of the boiler
designated in Table 4 must be performed to assure maximum
detailed instructions. Failure to service and maintain the
boiler and system could result in equipment failure.
Annual service and start-up procedure
Annual service call check list
(follow in the order listed below)
1
Check that boiler area is free from combustible
materials, gasoline and other flammable vapors
and liquids.
2
Check for and remove any obstruction to
combustion and ventilation air flow to boiler.
3
Check breeching and chimney or vent for
obstructions, damage, etc.
Repair or replace as necessary.
4
Clean boiler flueways.
See instructions in boiler manual.
5
Perform service on relief valve and circulator.
See instructions in boiler manual.
6
Check boiler and piping for leaks.
Repair if found.
7
Inspect and adjust burner. See burner manual
and:
8
Make sure boiler is filled with water.
9
Start unit and verify combustion settings with
combustion test equipment.
10
Verify operation of all controls on boiler.
See boiler manual and burner manual for
procedures.
Part number 550-141-986/0112
— Boiler Manual
to the boiler before any service operation
on the boiler except as noted otherwise
in this instruction manual. Failure to
turn off electrical power could result in
electrical shock, causing severe personal
injury or death.