Saeco IDEA Instruction And Maintenance page 174

Automatic espresso coffee machine
Hide thumbs Also See for IDEA:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 159
English
AUTOM. SWITCHING-ON
TIMES ON/OFF
COUNTERS
ANTI-FREEZING
UNBLOCK
AUTOM. SWITCHING-ON
This function enables the programming of automatic
switching-on and off of the machine, in two different time
ranges, every day of the week. By selecting:
-
"ON", the function can be programmed .
-
"OFF", the machine can only be switched on and off
manually, through the main switch (18).
Any automatic switching-on and off times previously
set, remain stored anyway.
-
To program the time ranges and the days see the fol-
lowing function "TIMES ON/OFF".
NOTE - The automatic switching-on of the machine is
possible only if the main switch (18) is on the "I"
position.
174
OFF
ON
ON 1: MTWTFSS 00:00
OFF1: MTWTFSS 00:00
ON 2: MTWTFSS 00:00
OFF2: MTWTFSS 00:00
ON 3: MTWTFSS 00:00
OFF3: MTWTFSS 00:00
ON 4: MTWTFSS 00:00
OFF4: MTWTFSS 00:00
COFFEE TOTAL 000000
WATER TOTAL 000000
ON
OFF
CODE: 0000
TIMES ON/OFF
This function enables to program the automatic switching-on
and off times over a whole week.
-
By selecting "TIMES ON/OFF", the cursor blinks on the
day to be modified.
-
Enter the day, using the button
small letter into a capital one.
-
Remove the day from the setting, using the button
(up), turning the capital letter into a small one.
-
Confirm the adjustment.
To set the time use the same procedure followed to set the clock.
Example: the function explanation scheme shows a machi-
ne programming which schedules the machine switching-on
at 08:00 and the switching-off at 18:00 from Monday to
Friday. The switching-on at 09:00 and off at 12:30 on
Saturday, and a stop over the whole Sunday.
COUNTERS
One of these two functions indicates the total number of
coffee brewing cycles; the other indicates the number of
hot water brewing cycles.
If the automatic dosing of hot water is disabled (see "HOT
WATER PROG." function), one cycle will be counted every
time the electrovalve is switched-on.
NOTE - Both functions cannot be reset and are just reference
functions.
ANTI-FREEZING
When the machine on "STANDBY" is exposed to low tem-
peratures, the anti-freezing function is important to prevent
the damages caused by icing-up in boilers. This function
keeps the boilers temperature at the minimum value to
prevent freezing.
-
By selecting "ON", the function is enabled.
-
By selecting "OFF", the function is disabled.
NOTE - This function can only be enabled if also function
"AUTOM. SWITCHING-ON" is on and if the machi-
ne is on "STANDBY". When the function is enabled
the message "ANTI-FREEZING"will be displayed.
UNBLOCK
This function enables to temporarily unblock the machine
when the number of cycles programmed for maintenance
and descaling has been reached. To get the unblock code
refer to the firm that has installed the machine or that sup-
plies maintenance. Then enter the code into the function:
-
Select "UNBLOCK"; the cursor will blink under the first
figure to be modified;
-
enter the datum and confirm;
-
after every confirmation, the cursor blinks under the fol-
lowing figure and goes on until the code is completed.