Di And Do - D-Link JustConnectDNR-2020-04P User Manual

16-channel poe network video recorder
Table of Contents

Advertisement

Section 3 - Configuration
The DI and DO page lets you manage four Digital Input (DI) and one Digital
Output (DO) devices connected to your NVR. It shows you the DI/DO
mapping and the current state of the device (Normally Closed (NC), Normally
Open(NO), or OFF).
For Digital Inputs 1-4:
When a DI is set to Normally Closed (N.C.), the normal state of the circuit is
closed to ground. In this scenario, events are triggered when the circuit is
opened, which then changes the status of the device to Open.
Example: The magnetic contacts on a window sensor that are broken during
a break-in will trigger an event.
When a DI is set to Normally Open (N.O.), the normal state of the circuit is
open. In this status, events are triggered when the circuit is closed to ground,
which then changes the status to Closed.
Example: A DI light switch that is turned on during off hours may close the
circuit and trigger an event.
For Digital Output:
• OFF indicates that the device is inactive and has not been triggered.
• ON indicates that the device is currently triggered.
Please go to the Event Settings on page 39 to select Digital Output as
the action and select the events that can act as triggers.
Click Save once you are done configuring your devices.
D-Link DNR-2020-04P User Manual