LG KP150Q Service Manual page 76

Table of Contents

Advertisement

CHECKING FLOW
START
Power is supplied t o
the bo ard?
Yes
LCD Displ ay OK?
Yes
Check C onnectio n
1. Cam Module
2. FPCB
Yes
Path s of Ca mera control
sig nals are OK?
Yes
FPCB OK?
Yes
Camera Prev iew Check?
Yes
Camera Working well
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
No
Fir st of all, Go to menu Baseband Camera Main LCD Preview
No
No
No
No
No
No
- 77 -
4. TROUBLE SHOOTING
Refer to
Power On Trouble
Refer to
LCD Di spl ay Trouble
Reconn ect FPCB or
Camera Module
Re-solder
Conne ctor
Replace t he FPCB
The Camera is broken.
Change th e Camera.
DBB have some problem .
Change th e DBB.