Pacific energy NEO 1.2 EU A SERIES Owners Manu page 19

Table of Contents

Advertisement

Ensure that the Masonry chimney
meets all National Fire Protection
Association and local building codes.
Have the chimney cleaned and
inspected by a professional to ensure
there are no cracks, weak mortar or
other signs of deterioration. See pipe
manufacturers installation instructions
for further information.
Minimum 7' (2.1m.)
Ceiling Height
*3" diameter air inlet with rodent screen
*If the crawl space is well ventilated it
is not necessary to extend air inlet to
outside
Figure 10: Venting to a masonry chimney.
120416-24_ NEO 1.2
52" (1.32m)
Minimum
48"
(1219 mm)
Non-combustible
oor protector
Fireclay Flue liner
Concrete cap
Chimney
As per local
and Federal codes
Chimney Connector
19
Installation Instructions
12"(305mm)
Minimum first
section of pipe
Hooded vent or
90 elbow turned down
5055.600EU-A
Approved
Through - Wall
Installation