Wiring A Power Connection; Using The 4-Pin Mini-Phoenix Connector For Data And Power; Using The 4-Pin Mini-Phoenix Connector For Data With External Power - AMX NXC-ME260/64 Instruction Manual

Hide thumbs Also See for NXC-ME260/64:
Table of Contents

Advertisement

Wiring a Power Connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming PWR and GND cables from
the external source must be connected to their corresponding locations on connector (FIG. 5).
1.
Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm connector. Match the wiring locations of the +/- on
both the power supply and the terminal connector.
2.
Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip the threads and damage
the connector.
3.
Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power supply.
PWR +
GND -
NXC-ME260/64
2-pin mini-Phoenix connector wiring diagram (direct power)
FIG. 5

Using the 4-pin Mini-Phoenix Connector For Data and Power

Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx device as shown in FIG. 6.
To the Integrated Controller's
AxLink/PWR connector
Top view
Mini-Phoenix connector wiring diagram (direct data and power)
FIG. 6

Using the 4-pin Mini-Phoenix Connector For Data With External Power

To use the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector for data communication and power transfer, the incoming
PWR and GND cable from the 12 VDC-compliant power supply must be connected to the AxLink cable connector going to the
Integrated Controller. FIG. 7 shows the wiring diagram. Always use a local power supply to power the Integrated Controller unit.
To the Integrated Controller's
AxLink/PWR connector
Top view
4-pin mini-Phoenix connector wiring diagram (using external power source)
FIG. 7
NOTE: When you connect an external power supply, do not connect the wire from the PWR terminal (coming from the external device)
to the PWR terminal on the Phoenix connector attached to the Controller unit. Make sure to connect only the AXM, AXP, and GND wires
to the Controller's Phoenix connector when using an external power supply.
Make sure to connect only the GND wire on the AxLink/PWR connector when using a separate 12 VDC power supply.

Do not connect the PWR wire to the AxLink connector's PWR (+) opening.

NXC-ME260/64 - Instruction Manual
To the external AxLink device
Local +12 VDC
PWR (+)
power supply
(coming from
GND (-)
an external
power supply)
Power Supply
Top view
To the external AxLink device
Top view
Connections and Wiring
11

Advertisement

Table of Contents
loading

Table of Contents