Modes And Front Panel Led Blink Patterns; Axlink Port And Led; Wiring Guidelines; Wiring Length Guidelines - AMX NXC-ME260/64 Instruction Manual

Hide thumbs Also See for NXC-ME260/64:
Table of Contents

Advertisement

Modes and Front Panel LED Blink Patterns

The following table lists the modes and blink patterns for the front panel LEDs associated with each mode. These patterns are not
evident until after the unit is powered.
Modes and LED Blink Patterns
Mode
OS Start
Boot
Contacting DHCP server On-board Master is contacting a DHCP server for IP configuration
Unknown DHCP server
Downloading Boot
firmware
No program running
Normal

AxLink Port and LED

The AxLink port and adjacent status LED on the front panel allows the NXC-ME260/64 to support AMX Legacy AxLink devices such
as G3 touch panels (ex: CP4/A) and PosiTrack Pilot devices.
A green LED shows AxLink data activity. When the AxLink port is operating normally, blink patterns include:
Off - No power, or the controller is not functioning properly

1 blink per second - Normal operation.

3 blinks per second - AxLink bus error. Check all AxLink bus connections.

The AxLink port can be used to supply power to downstream AxLink-compatible devices as long as both the power required is LESS
THAN 2 Amps total and the external power supply feeding the ME260/64 has the necessary power capability.

Wiring Guidelines

Use a 12 VDC-compliant power supply to provide power to the ME250/64 via the 2-pin 3.5 mm mini-Phoenix PWR connector on the
rear panel. Use the power requirements information described in the product's Specifications table to determine the power draw.
The incoming PWR and GND cable from the power supply must be connected to the corresponding locations within the PWR
connector.
CAUTION:
result in damage to the internal components and a possible burn out. Apply power to the unit only after installation is complete.

Wiring Length Guidelines

Refer to the following table for the wiring length guidelines based on wire size (gauge):
Wiring Guidelines - ME-260/64 @ 750 mA
Wire size
18 AWG
20 AWG
22 AWG
24 AWG

Preparing Captive Wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
NOTE: Never pre-tin wires for compression-type connections.
1.
Strip 0.25 inch (6.35 mm) of insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector types
described in this section).
3.
Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively doing so may strip the threads
and damage the connector.
NXC-ME260/64 - Instruction Manual
Description
Starting the operating system (OS).
On-board Master is booting.
information.
On-board Master could not find the DHCP server.
Downloading Boot firmware to the Master's on-board flash memory.
Note: Do not cycle power during this process!
There is no program loaded, or the program is disabled.
On-board Master is functioning normally.
This unit should only have one source of incoming power. Using more than one source of power to the Controller can
Maximum wiring length
144.51 feet (44.05 meters)
91.74 feet (27.96 meters)
59.17 feet (18.04 meters)
36.10 feet (11.00 meters)
Connections and Wiring
LEDs and Blink Patterns
STATUS
OUTPUT
INPUT
(green)
(red)
(yellow)
On
On
On
On
Off
On
On
Off
Fast Blink
Fast Blink
Off
Off
Fast Blink
Fast Blink
Fast Blink
On
Normal
Normal
1 blink per
Indicates
Indicates
second
activity
activity