Set Parity; Set Data Bits - Nortel CTA 500dm Installation Manual

Nortel networks digital modem installation guide
Table of Contents

Advertisement

Result Codes

Set Parity

Result Codes

Set Data Bits

P0873832 Issue 05
OK Appears when the value is supported.
ERROR Appears when the selected value is not recognized or is not
supported.
The Set Parity Command
sets the parity value of the interface between the CTA 500dm and the
attached computer. The following table shows the supported values.
Value
0
1
2
OK Appears when the value is supported.
ERROR Appears when the selected value is not recognized or is not
supported.Set Data Bits
The Set Data Bits Command sets the number of data bits on the
interface between the CTA 500dm and the attached computer. The
values 7 and 8 are permitted. The default value is 8 data bits.
Result Codes
OK Appears when the value is supported.
ERROR Appears the selected value is not recognized or is not
supported.
&P3=value
Use
none (default)
odd
even
&P4=value
CTA 500 dm On Line Guide