Removal Of The Three Way Diverter Valve; Removal Of The Diverter Group - Biasi Inovia ERP Series Service Manual

G.c. appl. no. 47-583-38, 47-583-39, 47-583-40, 41-583-30
Table of Contents

Advertisement

d
e
figure 8 .4

8 .4 removal of the three way diverter valve

1 Remove the front and both side case panels.
2 Empty the primary circuit and the d.h.w circuit of the boiler.
3 Remove the electric actuator (see "Removal of the electric
actuator" page 18).
4 Remove the fixing spring F (Figure 8.5)
5 Remove the three way diverter valve G by levering with a
screwdriver in as shown in Figure 8.5.
G
f
h
figure 8 .5
Reassemble the three way diverter valve carrying out the remov-
al operations in the reverse order.
warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water au-
thorities .
attention . when reassembling the three way diverter valve
be sure that the three way diverter is correctly oriented by
matching the reference h with the notch of the water group
figure 8 .5 .
Three way diverTer valve
c

8 .5 removal of the diverter group

1 Remove the front and both side case panels.
2 Empty the primary circuit and the d.h.w circuit of the boiler.
3 Remove the electric actuator (section "Removal of the elec-
tric actuator" page 18).
4 Remove the fixing spring I (Figure 8.6) and remove the pri-
mary circuit flow switch J.
J
i
figure 8 .6
5 Disconnect d.h.w. temperature probe K.
l
figure 8 .7
6 Unscrew the connector L (Figure 8.7), the c.h. flow connector
and the d.h.w. outlet connector.
7 Remove the d.h.w. heat exchanger (see "Removal" page
16).
8 Unscrew the screw M and remove the diverter group.
9 Reassemble the diverter group carrying out the removal op-
erations in the reverse order.
warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water au-
thorities .
K
m
- 19 -