OPERATION

NOTE: Operation is restricted to qualified person-
1
1. Turn on the gas valve. (Gas models only.)
2. Close the oven door.
3. Turn the SELECTOR Switch (1) to the desired
cook position.
The fan will start to turn and the temperature
control will go on.
4. Set THERMOSTAT (5) to the desired tempera-
ture.
The burner will ignite or the elements will come
on. The OVEN READY light (4) on the control
panel will illuminate.
For gas models if in starting, the burner does
not ignite within a few seconds, the RESET
alarm light (2) will go on. Press the RESET
switch (3) to restart the burner.
The LIGHT OFF OVEN READY light (4) will go
out when the oven has reached temperature.
NOTE: If the oven will not start after several at-
For the HUMIDAIRE control option:
1. When steam is desired, set the STEAM
CYCLE TIMER (8) to the required injection
time.
2. Momentarily press and release the STEAM
CYCLE START button (7). The STEAM indica-
tor (6) will light as water is injected into the
baking compartment.
Cool Down
1. Open oven door.
2. Turn the SELECTOR Switch (1) to COOL
DOWN.
Shut Down
1. Turn the SELECTOR Switch (1) to OFF.
2. Shut off the gas valve. (Gas models only.)
11
Operation
Solid State Controls
nel.
tempts contact a qualified installer.