Level Sensors (see figure K)
Clean the level sensors 35 occasionally.
– Unlock the latches 9 and remove the vacuum lid 8.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 8 again and lock the latches 9.
Storage and Transport (see figure L)
– Wind the mains cable around the cable holder 13.
– Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 15, crevice nozzle 25 in holder 16,
floor nozzle 28 in holder 17.
– Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
Correction of Malfunctions
Problem
The vacuum turbine does not start.
Vacuum turbine switches off.
Vacuum turbine does not restart after emptying
the container.
Vacuuming power decreases.
Dust escapes during vacuuming
The automatic shut-off (wet vacuuming) does
not respond.
Filter cleaning inoperative.
After-sales Service and Application Service
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the type plate of
the vacuum cleaner.
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
1 609 92A 0XC | (29.9.14)
– Mount the L-Boxx onto the retainers 7.
– To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 6.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 12, actuate the castor brakes 11 by
pushing down.
Corrective Measure
– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
35.
Mode selector switch 5 set to "Start/Stop automatic".
– Set mode selector switch 5 to the "vacuum" symbol and switch the power
tool connected to the socket outlet 3 on.
– Empty container 1.
– Switch vacuum cleaner off and wait 5 seconds; switch on again after
5 seconds.
– Clean level indicators 35 as well as the space between the level indicators 35
with a brush.
– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum hose 21 or
flat-fold filter 24.
– Replace disposal bag 23 or dust bag.
– Engage filter cover 34 properly.
– Mount vacuum cleaner lid 8 properly and lock latches 9.
– Replace flat-fold filter 24.
– Check proper installation of the flat-fold filter 24.
– Replace flat-fold filter 24.
– Clean level indicators 35 as well as the space between the level indicators 35
with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
– Monitor the level continuously.
– Push the SFC+ switch 18 toward the rear (position 1).
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0844) 7360109
E-Mail: boschservicecentre@bosch.com
Bosch Power Tools

Advertisement

Table of Contents
loading

Table of Contents