Flueing Arrangements - Horizontal; Terminations: All Systems; Flueing Arrangements - Vertical Terminations; Straight Vertical - Regency FG39-NG1 Owners & Installation

Freestanding gas stove
Hide thumbs Also See for FG39-NG1:
Table of Contents

Advertisement

INSTALLATION
Horizontal Terminations for All Fluing Systems
The shaded areas in the diagram below show all allowable combina-
tions of vertical runs with horizontal terminations. Maximum one
90
elbow (two 45
elbows equal one 90
O
o
LPG and NG:
Residential, Manufactured and Mobile Homes
Installations
The fluing arrangements diagrammed below, have a min. of 75% (flue
loss) efficiency with Fan Off, as required for manufactured homes. (Actual
efficiency may be as high as 85%)
May be installed in Manufactured (Mobile) Homes after first sale.
To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the flue restrictor plate to the correct position. Tighten
the screws.
10
FLUEING ARRANGEMENTS
elbow).
o

Flue Restrictor Position

Vertical Terminations Using
Dura-Flue Fluing System for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combi-
nations of straight vertical and offset to vertical runs with vertical
terminations. Maximum two 45
If the flue is ENCLOSED in a chase (min. size 9" x 9" / 229mm x 229mm)
maintain a 1-1/4" (32mm) clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Flue Restrictor setting at
40 Mj/h
Regency FG39-1 FireGenie Freestanding Gas Stove
elbows.
o
Flue Restrictor setting at
31 Mj/h