Technical Specifications - Lincoln Electric 180 User Manual

Wire feeder
Hide thumbs Also See for 180:
Table of Contents

Advertisement

Available languages

Available languages

A-1
TECHNICAL SPECIFICATIONS 180 Amp units (K2481-1, K2515-1, K2659-1, K2698-1)
Standard Voltage/Frequency
230 V
208 V
Voltage/Duty Cycle
230 V
30%
208 V
30%
Welding Current Range
30-180 Amps
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage/Frequency
230/208 V
60 Hz
Height
13.7 in
347 mm
1
If connected to a circuit protected by fuses use Time Delay Fuse marked "D".
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Only personnel that have read and
understood the WIRE FEEDER
WELDER Operating Manual should
install and operate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local or
other applicable electrical codes.
• The WIRE FEEDER WELDER power switch is
to be in the OFF ("O") position when installing
work cable and gun and when connecting
power cord to input power.
---------------------------------------------------------------------
INSTALLATION
INPUT – SINGLE PHASE ONLY
60 Hz
60 Hz
RATED OUTPUT
OUTPUT
Open Circuit Voltage
Fuse or Breaker Size
40 Amp Super Lag
PHYSICAL DIMENSIONS
Width
10.15 in
258 mm
WIRE FEEDER WELDER (180 MODEL)
Input Current
20 Amps @ rated output
20 Amps @ rated output
Current
130 Amps
130 Amps
34 V
Input Amps
1
20
Depth
18.2 in
462 mm
SELECT SUITABLE LOCATION
Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can
block air passages and cause overheating.
STACKING
WIRE FEEDER WELDER(180 MODEL) cannot be
stacked.
TILTING
Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.
Voltage at Rated Amperes
20
17.6
Wire Speed Range
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Minimum Input Cable
14 AWG
Weight
56 Ibs
25.4 kg
A-1

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents