SEC Cartridge/Heat Sink Assembly Removal (Mini Tower Chassis): Dell™ OptiPlex™ GX1p
 
To remove the SEC cartridge/heat sink assembly, follow these steps:
1.
Remove the system power
supply.
WARNING: The SEC cartridge/heat sink assembly can get extremely hot during system operations. Be sure that the assembly has had sufficient
time to cool before touching it.
2. Locate the SEC cartridge/heat sink assembly.
3. Disconnect the
microprocessor fan connector
connector and the MONITOR connector.
4. Release the 2 securing clips near the base of the heat sink from the metal standoffs.
5. Locate and press inward on the SEC cartridge release latches (located directly on top of the SEC cartridge adjacent to the heat sink assembly) until the latches
click.
6. Lift the SEC cartridge/heat sink assembly out of its guide bracket assembly/connector on the system board.
NOTE: When installing the SEC cartridge/heat sink assembly,  press outward on the SEC cartridge release latches and then carefully orient the 
assembly and press firmly with up to 25 pounds of force to mate the SEC cartridge with its connector. The SEC cartridge release latches will click into
the locked position as the assembly is seated.
 
 
from the 3-pin connector (labeled "FAN") on the system board. The connector is located between the SERIAL 2