Dell OptiPlex GX1p User Manual page 24

Hide thumbs Also See for OptiPlex GX1p:
Table of Contents

Advertisement

Memory address line failure at
address, read value expecting
value
Memory data line failure at
address, read value expecting
value
Memory double word logic
failure at address, read value
expecting value
Memory odd/even logic failure
at address, read value
expecting value
Memory write/read failure at
address, read value expecting
value
Memory allocation error
No boot device available
No boot sector on hard-disk
drive
No timer tick interrupt
Non-system disk or disk error
Not a boot diskette
Plug and Play Configuration
Error
Read fault
Requested sector not found
Reset failed
Sector not found
Seek error
Seek operation failed
Shutdown failure
Time-of-day clock stopped
Time-of-day not set
Timer chip counter 2 failed
Unexpected interrupt in
During memory test,
read at
value
was incorrect.
address
Software in use conflicts with operating
system, application, or utility.
System does not recognize diskette drive
or hard-disk drive from which it is trying
to boot.
Configuration settings in System Setup
program incorrect, or operating system
corrupted.
Timer on system board malfunctioning.
Indicates a fatal error.
Diskette in drive A or hard-disk drive
does not have bootable operating system
installed on it.
No operating system on diskette.
System encountered problem in trying to
configure one or more expansion cards.
MS-DOS® cannot read from diskette
or hard-disk drive.
System could not find particular sector
on disk, or requested sector defective.
Disk reset operation failed.
MS-DOS unable to locate sector on
diskette or hard-disk drive.
MS-DOS unable to locate specific track
on diskette or hard-disk drive.
System could not find particular address
mark on disk.
System board chip faulty. Indicates a
fatal error.
System battery low.
Time or Date setting in System Setup
program incorrect, or system battery
bad.
Timer circuit on system board
malfunctioning. Indicates a fatal error.
Keyboard/mouse controller
controller (defective system board).
Faulty or improperly seated DIMMs or
defective system board.
Faulty application or utility.
Faulty diskette, diskette/tape drive
subsystem, hard-disk drive, hard-disk
drive subsystem; or no boot disk in drive
A.
Incorrect configuration settings in System
Setup program, or no operating system
on hard-disk drive.
Defective system board.
Faulty diskette, diskette/tape drive
subsystem, or hard-disk drive
subsystem.
No operating system on diskette.
System resource conflict.
Faulty diskette, or hard-disk drive.
Improperly connected diskette/tape
drive, hard-disk drive interface cable, or
power cable.
Defective sectors on diskette or hard-
disk drive.
Defective diskette or hard-disk drive.
Faulty diskette or hard-disk drive.
Defective system board.
Defective battery or faulty chip
(defective system board).
Incorrect Time or Date settings, or
defective system battery.
Defective system board.
Improperly seated DIMMs or faulty

Advertisement

Table of Contents
loading

Table of Contents