Technical Data

The following table lists input values for the appliance.
Burner
Orifice Size
I
Main
1.04mm (59)
1.51mm (53)
Back
1.51mm (53)
2.26mm (43)
Side*
1.02mm (60)
1.45 mm
Total of all burners which can be operated simultaneously 19.7 kW
* RSIB unit only
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
I
3B/P(30)
Orifice Sizes(see
I
above)
Gases / Pressures Butane and
Propane at
30mbar
Countries
BE, BG, CY,
DK, EE, FI,
FR, GB, HR,
HU, IS, IT, LT,
LU, MT, NL,
NO, RO, SE,
SI, SK, TR
Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the table
above. The grill is equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5 mbar
for propane/butane and 18.5 mbar for natural gas and must not be modified or adjusted. For replacement, use
only the regulator specified by the manufacturer.
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are in
the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to property,
serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing
Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
(Gross) Heat Input (Total)
II
16 kW
3.7 kW
16 kW
I
I
I
3+(28-30/37)
3B/P(37)
3B/P(50)
I
I
I
Butane 28-30mbar
Butane and
Butane and
Propane 37mbar
Propane at
Propane at
37mbar
50mbar
BE, CH, CY, CZ, ES,
PL
AT, CH, DE, SK AT, BG, CH,
FR, GB, GR, IE, IT,
LT, LU, LV, PT, SK, SI
I
1160 g/hr
8 kW
580 g/hr
268 g/hr
1428 g/hr
1160 g/hr
I
I
2H
2E
II
II
G20 at
G20 at
20mbar
20/25 mbar
DE, LU, PL
CZ, DK, EE,
ES, FI, GB,
GR, HR, HU,
IE, IS, IT, LV,
LT, NO, PT,
RO, SE, SI,
SK, TR
5
Gas Usage (Total)
II
1520 L/hr
760 L/hr
352 L/hr
1872 L/hr RSIB
1520 L/hr RB
I
I
2E+
2L
II
II
G20/G25 at
G25 at
20/25 mbar
25mbar
BE,FR
NL
www.napoleongrills.com