2. WIRING
12D-SFA-CV (100 m)
Dimensions in millimeters.
Outer Sheath
Armor
Inner Sheath
80
Cover with heat-shrink tubing and heat.
30
Nut
Washer
Clamp Nut
2-4
Shield
12
Clamp
Gasket
1.8
4.5
Pin
Solder through the hole.
How to fabricate antenna cable 12D-SFA-CV
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Twist shield end.
Slip on clamp nut, gasket and clamp as shown left.
Expose the insulator by 1.8 mm.
Expose the core by 4.5 mm.
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)