How to use electronic circuit diagram
TIMER TABLE
Name
Sleep Mode Waiting
Sleep Mode Operation
Real Timer
Time Delay Safety Control
Forced Operation
Time Save Control
Anti-Freezing
Auto Mode Judgement
Soft Dry
Deodorizing Control
Comp. Reverse Rotation Detection
Comp./ Fan Motor Delay Timer
Powerful Mode Operation
Random Auto Restart Control
4 Way Valve
After Deice Ended
Hotstart Delay Times
Hotstart Finish Times
Time
1 hr.
8 hrs.
1 hr.
10 min.
1 min.
2 min. 58 sec.
60 sec.
7 min.
4 min.
25 sec.
OFF
6 min.
ON
10 min.
Cooling
40 sec.
70 sec.
20 sec.
180 sec.
Soft Dry
40 sec.
360 sec.
5 min.
2 min.
1.6 sec.
15 min.
0 ~ 62 sec.
5 min.
30 sec.
4 min.
2 min.
Test Mode
(When test point
Short-circuited)
6 sec.
48 sec.
1 min.
10 sec.
1 sec.
0 sec.
0 sec.
42 sec.
0 sec.
0 sec.
36 sec.
60 sec.
4 sec.
7 sec.
2 sec.
18 sec.
4 sec.
36 sec.
30 sec.
Comp. ON 5 min. and above
0 sec.
0 sec.
15 sec.
0 ~ 6.2 sec.
30 sec.
3 sec.
0 sec.
0 sec.
73
CS-W18CKP CU-W18CKP5 / CS-W24CKP CU-W24CKP5
Remarks
Soft Dry: 10 min. operation
Comp. OFF after deice