Convenience Operation - Panasonic CS-W18CKP Service Manual

Hide thumbs Also See for CS-W18CKP:
Table of Contents

Advertisement

CS-W18CKP CU-W18CKP5 / CS-W24CKP CU-W24CKP5
I Setting the Fan Speed
• Press 4 to select:-
FAN
FAN
FAN
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction.
• Press 5 to select:-
AUTO
AUTO
For COOL/DRY operation.
Swing up/down automatically.
For HEAT operation
AUTO
(For Heat Pump Model only)
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.
I Setting the Horizontal Airflow Direction.
• Press 6 to select:-
Indoor
Horizontal
Unit
Airflow
Direction
Remote
Control
For COOL/DRY operation.
AUTO
Swing left/right automatically.
For HEAT operation
AUTO
(For Heat Pump Model only)
There is no air swing during the discharge
air temperature is low. When the
temperature rises, the horizontal airflow
louvers swing left/right automatically.
AUTO HEAT
8
POWERFUL
MODE
7
1
ON
5
OFF
CHECK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
I ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
I OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
G Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
Cooling Model
COOL,DRY, – 15 minutes
AUTO
in advance
• Once the ON-Timer is set, operation will start at the
set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
G Use this air conditioner under the following
conditions:
– Low Fan Speed
– Medium Fan Speed
– High Fan Speed
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
AUTO
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
COOL
DRY FAN
AUTO
AUTO
FAN

CONVENIENCE OPERATION

OFF/ON
I Sleep Mode Operation
To obtain a comfortable room temperature while
ECONOMY
SLEEP
6
sleeping:-
• Press 6.
AIR SWING
FAN SPEED
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
1
2
3
3
SET
G Sleep Mode Operation Details
4
CANCEL
• When the room temperature reaches the set
2
TIMER
RESET CLOCK
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a
S
T
e
e
m
t
p
t
e
i
n
a
g
u
e
Temperature
S
T
Heat Pump Model
e
e
m
t
p
t
e
i
COOL,DRY, – 15 minutes
r
n
a
in advance
g
t
HEAT, AUTO – 30 minutes
u
in advance
r
e
Cooling Model
(Unit in °C)
Indoor
Outdoor
DBT
WBT
DBT
WBT
32
23
26
43
16
11
11
16
Heat Pump Model
(Unit in °C)
Outdoor
Indoor
DBT
WBT
DBT
WBT
32
23
43
26
(30)
(-)
(24)
(18)
16
11
16
11
(16)
(-)
(-5)
(-6)
temperature, the airflow volume will change to low
automatically.
priority.
Cooling Model
Temperature
Approx. 0.5°C
increase.
Approx.
0.5°C
increase.
• Cooling or Soft Dry
Sleep
Operation for sleep shift
r
Operation
operation will start to
Sleep shift
button is
avoid overcooling.
operation
t
pressed.
starts.
r
← 1 hour →
0~1 hour
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Heat Pump Model
Approx. 0.5°C
increase.
Approx.
0.5°C
• Cooling or Soft Dry
increase.
Operation for sleep shift
operation will start to
avoid overcooling.
Sleep shift
operation starts.
• Heating operation for
sleep shift operation will
Sleep
start to avoid overheating.
Operation
Approx. 2°C
button is
← 1 hour →
decrease.
pressed.
Approx. 3°C
← 1 hour →
decrease.
0~1 hour
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
32
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).
I Economy Mode Operation
To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press 7.
* Economy mode indicator (green) on the indoor unit
will light up.
• Press once more to cancel this operation.
I Powerful Mode Operation
To obtain the set temperature quickly.
• Press 8.
* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
G Economy / Powerful Mode Operation Details
• Economy and Powerful operation cannot be
selected simultaneously.
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If sleep button or operation mode button is pressed,
economy or powerful operation will be cancelled.
• During FAN – Air circulation operation, the powerful
Time
and economy operation are not available.
(cooling model only)
Economy Mode
Temperature
Operation
0.5°C higher
COOL / DRY
than set temp.
HEAT
0.5°C lower
(for Heat Pump
than set temp.
model only)
Powerful Mode
Temperature
Operation
3°C lower
COOL / DRY
than set temp.
HEAT
3°C higher
(for Heat Pump
than set temp.
model only)
Airflow
volume
Super Low
Automatic
Airflow
volume
Super High
Automatic