Henny Penny OFE-322 Technical Manual page 20

Cfa electric open fryer
Hide thumbs Also See for OFE-322:
Table of Contents

Advertisement

2-10. HEATING
CONTACTORS
(Continued)
2-9
Checkout (Power Supplied)
To avoid electrical shock, make connections before
applying power, take reading, and remove power before
removing meter leads. The following checks are
performed with the wall circuit breaker closed and the
main power switch in the ON position.
1. Re-apply power to unit and turn POWER switch ON.
2. Using illustrations from previous page, check voltage as
follows:
Test Points
From terminal 34 to 35
From terminal 35 to 36
From terminal 34 to 36
Mercury Contactor Replacement:
If either contactor is defective it must be replaced as follows:
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle, to the frypot
to be worked on. Be aware the other controls will have
power.
1. Remove only the wires directly connected to the contactor being
replaced. Label the wires for replacement.
2. Loosen the screws securing the contactor bracket to the shroud.
3. Remove the contactor from the bracket.
4. Reinstall in reverse order.
Results
The voltage should read
the same at each terminal
405