4. Troubleshooting
4-2 Electrical Malfunction
No power
No display
*Check terminal block voltage.
AC 240V/120V or AC208V/120V
*Thermostat open check. (150°c / 0°c )
*Check the pin voltage of connector
(CN01) on Main PCB.
(Input voltage : 120V)
Check the Low voltage Transformer
IC02(7812)
IC02(7812)
IC03(7805)
IC03(7805)
Connector
Connector
CN09(AC 120V)
CN09(AC 120V)
(Terminal Block)
(Terminal Block)
L1
L1
or
(Black)
(Black)
No
Yes
Yes
Yes
No
Low Voltage Transformer
Low Voltage Transformer
ZNR1
ZNR1
(Varistor)
(Varistor)
L1
L2
L2
L1
(Red)
(Red)
L2
N
N
(White)
(White)
* Reset the circuit breaker
or check main power.
END
No
* replace Thermostat.
Thermostat
Thermostat
(150/0)
(150/0)
**Reconnect and replace or
repair harness is damaged
Check whether varistor(ZNR1) on
main PCB has been damaged.
Yes
* replace Main PCB.
63
L2 : 240V
N : 120V
N : 120V
END