Safety Information - Pioneer PD-F1007 Service Manual

Hide thumbs Also See for PD-F1007:
Table of Contents

Advertisement

PD-F1007

1. SAFETY INFORMATION

This service manual is intended for qualified service technicians; it is not meant for the casual
do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been
trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.
IMPORTANT
THIS PIONEER APPARATUS CONTAINS
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUCTED PERSON.
LABEL CHECK
2
PD-F1007/MY
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 7 mw
WAVELENGTH: 780 – 785 nm
Additional Laser Caution
1. Laser Interlock Mechanism
The position of the switch (VSK1011) for detecting
loading state is detected by the system microprocessor,
and the design prevents laser diode oscillation when
the switch (VSK1011) is not on CLMP terminal side
(CLMP signal is OFF or high level).
Thus, the interlock will no longer function if the switch
(VSK1011) is deliberatery set to CLMP terminal side. (low
level)
The interlock also does not function in the test mode *.
Laser diode oscillation will continue, if pin 33 of
CXA1782CQ (IC151) on the MOTHER BOARD ASSY
is connected to GND, or pin 89 of IC351 (LDON) is
connected to low level (ON), or else the terminals of
Q151 are shorted to each other (fault condition).
2. When the cover is opened, close viewing of the
objective lens with the naked eye will cause exposure
to a Class 1 laser beam.
Refer to page 35 .