New Buck Corporation CDVB200 Owner's Operation And Installation Manual page 12

Cast stove and direct-vent natural or l.p. (liquid propane) freestanding gas stove heater
Table of Contents

Advertisement

EXTERIOR VENT LOCATIONS and RESTRICTIONS
INSIDE CORNER DETAIL
G
V
A
D
E
B
L
A. Clearance above grade, veranda, porch, deck, or
balcony (*12 inches (30cm) minimum)
B. Clearance to window or door that may be opened (*12
inches (30cm) minimum.)
C. Clearance to permanently closed window (minimum 12
inches (30 cm)) recommended to prevent condensation on
window.
D. Vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 24 inches (60cm)
from the center-line of the terminal (18 inches (46cm)
minimum.)
E. Clearance to unvented soffit (12 inches (30cm)
minimum.)
F. Clearance to outside corner - 6 inches (15 cm)
G. Clearance to inside corner - 12 inches (30 cm)
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings
and serves both dwellings.
As specified in "M" above, only permitted if verandas, porches, decks, or balconies is fully open a minimum of two sides
beneath the floor.
*As specified in CGA B1:19 Installation Codes (1991). NOTE: Local codes or regulations may require different clearances.
TERMINATION BOX, LOCATION CHART
C
FIXED
CLOSED
V
V
F
B
B
OPENABLE
V
A
= VENT TERMINAL
= AIR SUPPLY INLET
Figure 17– Minimum Clearances fo Vent Terminations
H
B
V
FIXED
CLOSED
B
J
V
A
A
= AREA WHERE TERMINAL IS NOT PERMITTED
H. *Not to be installed above a meter regulator assembly
within 3 feet (90 cm) horizontally from the centerline of the
regulator.
I. Clearance to service regulator vent outlet (*6 feet (1.8
m) minimum.)
J. Clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other appliance (*12
inches (30 cm) minimum.)
K. Clearance to a mechanical air supply inlet (*6 feet (1.8
m) minimum.)
L. Clearance above paved sidewalk or a paved driveway
located on public property (*7 feet (2.1m) minimum).
M. Clearance under veranda, porch, deck, or balcony, (*12
inches (30 cm) minimum).
8
INSTALLATION
M
I
V
A
K

Advertisement

Table of Contents
loading

Table of Contents