Serial (Rs232C) Connector Command Reference; I Serial (Rs232C) Communication Protocol; I Command Format - Panasonic WJ-HD309 Operating Instructions Manual

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

SERIAL (RS232C) CONNECTOR COMMAND REFERENCE

I SERIAL (RS232C) Communication Protocol

SERIAL (RS232C) means the EIA standard number of an interface for serial data transfer. With the SERIAL (RS232C) interface,
you can control functions of this unit by transferring the specified commands from a personal computer (PC) to this unit.
Notes:
• This unit does not support the communication converted between the SERIAL (RS232C) and USB interface.
• When controlling the unit with the SERIAL (RS232C) interface, the following parameters should be identical between the
communication devices.
The setting is available in "SETUP MENU" – "Comm" – " SERIAL (RS232C) Setting".
Baud Rate
Data Bit
Parity
Stop Bit

I Command Format

The following pages detail how to write the commands.
1. The following details how to write the commands
Code
[STX] AD [Unit address of this unit] [Transmission Command] : [p] [ETX]
ASCII
(02H) – – – – – – – – – – – – – – – – – – – – – – – – – – – (03H)
STX: This shows the data start. STX (ASCII code: 02h) is always prefixed to data. h shows hexadecimal digit.
Transmission command: A command shown in the Command List is designated.
ETX: This shows the data end. ETX (ASCII code: 03h) is always prefixed to data.
The character code is ASCII.
When a command needs parameter, colon (:) is used for dividing the command and parameter. The following is how to
write the commands when two or more commands are specified.
Code
[STX] AD [Unit address of this unit] [Transmission Command] : [p1] : [p2] [ETX]
2. Response Command (from the Unit to the PC)
The unit sends back the response command for the transmission command from the PC.
• When the reception was completed successfully
The response command differs between when an ANSWER command (sending back the status or data) is required or
when not required.
• When no ANSWER command is required
The unit sends back the same identifier as that in the transmission command, as shown in the figure.
Transmission command (→ The unit)
[STX]
OPL
[ETX]
Same identifier
Response command (← The unit)
[STX]
OPL
[ETX]
137