Menu item
Description
Lin Key
Adjust the linear key density.
Adjust (2/2)
Lin Key
Turn the clean mode for the linear key on/
Mode
off. When the clean mode is on, the key
source does not affect the key fill, which
is added unchanged to the background.
Tip
Clean mode is effective when you are
using signals consisting of a paired key
fill and key source, as with a character
generator.
Chromakey
Display the [Auto Chromakey] menu
Auto Adj
(page II-27) that allows you to specify a
part of the foreground video (e.g., the
blue background color) and use it as a
reference for automatically creating the
chroma key image.
Chromakey
Display the [Manual Chromakey] menu
Manual Adj
(page II-28) for making detailed
adjustments to the chroma key.
Key Invert
Invert white and black of the key source.
Key Wipe
Set the key wipe direction and key wipe
pattern.
You can also press the V1 knob to display
the [Key Wipe Modify] menu (page II-29).
Key Wipe
Defocus the edge of a key wipe pattern
Edge
(soft edge).
Key DME
Set the key DME wipe direction and key
Wipe
DME wipe pattern.
You can also press the V1 knob to display
the [Key DME Wipe Modify] menu (page
II-30).
II-24
Details on [Key] Menu
Knob Parameter Meaning
V4
Dens
Key density
V4
Clean
Turns clean
mode on/off
V1
Auto
Press the knob
to display the
[Auto
Chromakey]
menu
V1
Manual
Press the knob
to display the
[Manual
Chromakey]
menu
V4
Invert
Turns key source
inversion on/off
V1
Modify
Press the knob
to display the
[Key Wipe
Modify] menu
V3
Direct
Key wipe
direction
V4
PtnNum
Key wipe pattern
number
V3
Soft
Turns soft edge
on/off
V4
Param
Defocus
condition for
edge
V1
Modify
Press the knob
to display the
[Key DME Wipe
Modify] menu
V3
Direct
Key DME wipe
direction
V4
PtnNum
Key DME wipe
pattern number
Setting range
Reference
page
0 to 100.00
Off, On
Operating
Instructions
(Basic
Operation)
II-21
Off, On
II-20
Norm (normal),
II-20
N/R (normal/
reverse), Rev
(reverse)
1 to 24
Off, On
0.00 to 100.00
II-20
Norm (normal),
N/R (normal/
reverse), Rev
(reverse)
1001 to 1008
(Slide), 1021 to
1031 (Squeeze),
1041 to 1044
(Door), 1201 to
1208, 1221 to
1224 (Frame In/
Out)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents