Main Power; Changing Single Circuit To Two Circuits; Field Wiring - Bradford White Brute Deluxe BMT2H Installation And Operation Instructions Manual

Hide thumbs Also See for Brute Deluxe BMT2H:
Table of Contents

Advertisement

(
Brute Deluxe
500-2000), Install & Operating
The appliance must be electrically grounded in
accordance with the requirements of the authority having
jurisdiction or, in the absence of such requirements, with
the latest edition of the National Electrical Code, ANSI/
NFPA 70, in the U.S. and with latest edition of CSA
C22.1 Canadian Electrical Code, Part 1, in Canada. Do
not rely on the gas or water piping to ground the metal
parts of the boiler. Plastic pipe or dielectric unions may
isolate the boiler electrically. Service and maintenance
personnel, who work on or around the boiler, may be
standing on wet floors and could be electrocuted by an
ungrounded boiler.
Single pole switches, including those of safety
controls and protective devices must not be wired in a
grounded line.
All electrical connections are made in the field
wiring terminal strip, which is located at the right side of
the appliance.
NOTE: All internal electrical components have been pre-
wired. No attempt should be made to connect electrical
wires to any other location except the wiring box.

5.1 Main Power

All Brute Deluxe non-pump-mounted heaters
require a single 120-volt fused supply. See
over current protection ratings.
Pump-mounted Brute Deluxe models 500 to
1500 use a single 120-volt fused supply. The installer
can change these units to use a separate circuit for the
pump, if desired. Instructions to make this change are
found in
Section 5.1.1.
Pump-mounted Brute Deluxe models 1750 and
2000 require two 120-volt fused supplies. See
for over current protection ratings.
SINGLE CIRCUIT CONN.
SIZE
HEATER
W/O PUMP
500
15
750
15
1000
20
(TACO) 25 / 30 (B&G)
1250
25
1500
25
1750
25
2000
25
Figure 15. Field Wiring.
WARNING
Figure 15
Figure 15
PUMP
ONLY
ONLY
W / PUMP
TACO
20
15
20
15
15
30
15
30
15
15
20
5.1.1 Changing Single Circuit to Two
Circuits
Sizes 500 to 1500 will be shipped from the factory
for a single 120-volt power supply. To use a separate
circuit for the pump:
1. Ensure power is disabled to the unit.
2. Remove the three jumper wires that connect the
L2, N2 and GROUND wires on terminal block 1
to the main distribution terminal block. These
wires will be black/white, white and green
respectively.

5.2 Field Wiring

Main Power: The main field wiring connection
points are located inside the line voltage connection/
for
PUMP
B&G
15
15
15
15
15
20
20
Figure 16. Brute Deluxe (500–750) Wiring Diagram.