11.5. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in Check Point (Handset)(P.38).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG6621RU (for KX-
TG6611RU),
PNZZTG6621UA
PNZZTG6621CA (for KX-TG6611/12CA)
11.5.1. Connections
1
Connect the DC Power or Battery to BATT+ and BATT-.
2
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
3
DC Power
1
or Battery
Note:
*: COM port names may vary depending on what your PC calls it.
(for
KX-TG6611UA),
URX
BATT+
Handset P. C. board
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E),
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
R2
R3
R4
R7
URX (red)
3
3
UTX (yellow)
UTX
GND (black)
2
GND
BATT-
JIG Cable
51
change
the
following
Old value (kΩ)
New value (kΩ)
22
3.3
22
3.3
22
4.7
4.7
10
To Serial Port
(com port 1*)
PC
values
of