U-Line 3018CLR User Manual page 59

18" clear ice machine
Hide thumbs Also See for 3018CLR:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
ID
Description
Time To
Water
Clean
circulation
system
requires
cleaning.
Blocked
Drain pump
Drain
has detected a
problem.
To access All Errors follow the steps below.
1. Use Down
to select "All Errors".
2. Press Select
.
3. Use Up
and Down
information.
To clear the error log use Down
and press Select
to confirm.
To exit the Actual Temps menu use Up
"Return to Menu" and press Select
Relay Status
Up
MULL COND DEF
OFF
Down
Relay status displays the current state of each relay. While
all available relays are displayed, only a portion are used.
ID
Description
Mull
Mullion Heater
Cond
Condenser Fan
Def
Defrost Valve
LVLV
Left Valve
RVLV
Right Valve
Pan
Pan Heater
Comp
Compressor
Solution
Clean unit with 37050 cleaner.
Check drain hose for restriction
or drain pump for correct
operation.
to scroll through available
to select "Clear Errors"
to select
to confirm.
Select
RETURN TO MENU
RELAY STATUS
LVLV
OFF
OFF
OFF
Status
Not Used
Used
Not Used
Not Used
Not Used
Not Used
Used
ID
Description
WV
Water Valve
Pump
Circulation Pump
Harvest
Harvest
Note: The Cond (Condenser Fan) will switch state with the
compressor relay, however the condenser fan is actually
powered through a DC output and is independent of the
Cond relay. Condenser fan status can be viewed through
the "Output" service menu option.
To access Relay Status
1. Use Down
to select "Relay Status".
2. Press Select
.
3. Use Up
and Down
information.
To exit the Relay Status simply press Select
Relay Toggle
Up
Down
Relay toggle is used to manually switch the state of each
relay to test for proper operation. In addition to the AC
relays, DC outputs may also be toggled. Relay toggle can
also be used to force the unit into a particular state. For
example, to force a 3018 / 3045 into a cooling cycle
activate Comp, F1, and F3.
ID
Description
Cond
Fan
LVLV
Left Valve (Not Used)
RVLV
Right Valve (Not Used)
Pan
Pan Heater (Not Used)
Comp
Compressor
F1
Evaporator Fan (Not Used)
F2
Evaporator Fan (Not Used)
u-line.com
Status
Used
Used
Used
to scroll through available
to exit.
Select
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF
Type
AC
AC
AC
AC
AC
DC
DC
Control Operation - Service 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents