EnGLiSh
injector table
Category ii2h3B/P
Type of gas used
NATURAL GAS
(Methane)
G20
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Type of gas
used
G20 20 mbar
G30/ G31
30 mbar
Electric Power: 220 - 240 V ~ 50/60 Hz
Type of
injector
burner
marking
power burner
145
rapid
118 F2
semi-rapid
101 Z
auxiliary
72 X
power burner
96
rapid
85
semi-rapid
69
auxiliary
50
Model
Rated thermal
configuration
flowrate (kW)
5 BURnERS
1 PB - 1 R
2 SR - 1 AUX
1 PB - 1 R
2 SR - 1 AUX
Rated
Rated
thermal
consumption
flow rate
kW
4,00
381 l/h
3,00
286 l/h
2,00
190 l/h
1,00
95 l/h
3,80
276 g/h
3,00
218 g/h
2,00
145 g/h
1,00
73 g/h
Total rated
consumption
12,00
11,80
Reduced
Gas pressure
heat
(mbar)
capacity
min. rat. max.
kW
2,20
0,60
17
0,35
0,30
1,90
0,60
20
0,35
0,30
Air required (m
for burning1m
gas
1142 l/h
857 g/h
1 1
20
25
30
35
)
3
of
3
9,52
30,94

Advertisement