Operating Tips; Operation And Performance - Fujitsu AGYG14LVCB Operating Manual

Hide thumbs Also See for AGYG14LVCB:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
TROUBLESHOOTING
NORMAL
The damper opens and
FUNCTION
closes automatically
Doesn't operate at all:
CHECK ONCE
MORE
Poor Cooling (or Heating)
performance:
The unit operates
differently from the Remote
Controller's setting:
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (Fig. 3 6)
and the TIMER Indicator Lamp (Fig. 3 7) fl ashes, and ECONOMY Indicator Lamp (Fig.3 8) fl ashes fast. Immediately stop opera-
tion, turn off the electrical breaker and consult authorized service personnel.

OPERATING TIPS

Operation and Performance

Heating Performance
● This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi cient
heating performance is being produced, we recommend
you use this air conditioner in conjunction with another kind
of heating appliance.
● Heat-pump air conditioners heat your entire room by recir-
culating air throughout the room, with the result that some
time may be required after fi rst starting the air conditioner
until the room is heated.
En-18
Symptom
● The damper is automatically controlled by a microcomputer accord-
ing to the airfl ow temperature and operation time of the air condi-
tioner.
Symptom
● Has the circuit breaker been turn off?
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the timer operating?
● Is the Air Filter dirty?
● Air the air conditioner's intake grille or outlet port blocked?
● Did you adjust the room temperature settings (thermostat) correctly?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight
to enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
● Make sure the lower air outlet is not choked with foreign matters,
causing abnormal operation to damper.
● Is the unit set for SUPER QUIET operation?
● Are the Remote Controller's batteries dead?
● Are the Remote Controller's batteries loaded properly?
Problem
Items to check
Microcomputer-controlled Automatic Defrosting
● When using the Heating mode under conditions of low out-
door temperature and high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate brief-
ly (for about 7-15 minutes).
During Automatic Defrosting operation, the OPERATION
Indicator Lamp (green) will fl ash.
● After heating operation stops, if frost forms on the outdoor
unit, the unit will start Automatic Defrosting operation. At
this time, the outdoor unit will automatically stop after oper-
ating for a few minutes.
(However, some type of multi-type air conditioner doesn't
provide this function.)
See Page
See Page
8–9
7
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoyg14lvcb

Table of Contents