Shock And Vibration; Electromagnetic Compatibility - National Instruments NI PXIe-8130 User Manual

Embedded computer kit
Hide thumbs Also See for NI PXIe-8130:
Table of Contents

Advertisement

Appendix A
Specifications

Shock and Vibration

Note
Specifications are subject to change without notice.
Safety
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/certification
appropriate link in the Certification column.

Electromagnetic Compatibility

For EMC compliance, operate this device according to product documentation.
Note
NI PXIe-8130 User Manual
Operating Shock .....................................30 g peak, half-sine, 11 ms pulse
Random Vibration
Operating .........................................5 to 500 Hz, 0.3 g
Nonoperating ...................................5 to 500 Hz, 2.4 g
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
IEC 61010-1, EN-61010-1
UL 61010-1, CSA 61010-1
, search by model number or product line, and click the
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
EN 61326 EMC requirements; Minimum Immunity
EN 55011 Emissions; Group 1, Class A
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
(with solid-state hard drive)
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
A-4
rms
rms
ni.com