Specifications; Table Of Contents - Napoleon EPA 1100 Installation And Operation Instructions Manual

Napoleon fireplaces hi-tech listed solid fuel burning stoves and inserts installation and operation instructions epa 1100, epa 1100l, epa 1100c, epa 1400, epa 1400l, epa 1900, epi 1101, epi 1401
Table of Contents

Advertisement

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2-4 INTRODUCTION
PG
Warranty
General Information
Care of Plated & Enamelled Parts
Care of Glass
5-6 INSTALLATION
Installing the Legs
Alcove Installation
Stove Installation
Chimney Connection
Adding Chimney Sections
Outside Air
6-7 MOBILE HOME INSTALLATION
Venting
Outside Air
7-8 FIREPLACE INSERT
INSTALLATION
Prior to Installation
Installation into a Masonry Fireplace
Installation into a Factory Built Fireplace
8-9 OPTIONAL FAN
INSTALLATIONS
Stove Models
Insert Models

SPECIFICATIONS

WIDTH
DEPTH
DEPTH BEHIND FLASHING
FLUE CENTERLINE TO REAR
FLUE CENTERLINE TO SIDE
PEDESTAL MODEL
CAST MODEL
HEIGHT
LEG MODEL
CHAMBER (D.W.H.)
CAPACITY
APPROX. AREA HEA TED*
HEA T OUTPUT (HIGH BURN)**
DURA TION LOW FIRE*
WEIGHT W/O BRICKS
WEIGHT OF BRICKS
*FIGURES WILL VARY CONSIDERABLY WITH INDIVIDUAL CONDITIONS.
** WOLF STEEL LTD. ESTIMATED REALISTIC BTU/H WITH HARDWOOD LOGS AND REGULAR REFUELING.
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.

TABLE of CONTENTS

MODEL 1100,
MODEL 1101
1100C& 1100L
(INSERT)
25 1/2 in. (65 cm)
28 in. (71 cm)
22 1/2 in. (57 cm)
24 in. (61 cm)
16 1/2 to 21 in.
(42 to 54 cm)
6 1/2" (16.51 cm)
11" (27.94 cm)
12 3/4" (32.39 cm)
14" (35.56 cm)
33 1/4 in. (84cm)
21 1/4 in. (55cm)
28 1/2 in. (72cm)
32 in. (81cm)
13-1/2x18x12in.
13-1/2x18x12in.
(34 x 46 x 31 cm)
(34 x 46 x 31 cm)
1.7 ft
(0.05 m
)
1.7 ft
3
3
3
600-1200 ft
600-1200 ft
2
(56-112 m
2
)
(56-112 m
50,000 BTU
50,000 BTU
7 HOURS
7 HOURS
215 lbs (97.5 kg)
185 lbs (83.9 kg)
110 lbs (50 kg)
120 lbs (54.4 kg)
10-11 FINISHING
Brick Installation
Ornamental Trivet Installation
Door and Handles Installation
Pedestal Trim Installation
11-13 OPERATING INSTRUCTIONS
Achieving Proper Draft
Fire Extinguishers and Smoke Detectors
Fuel Loading and Burn Cycle
Flash Fire
Extended Fire
Smoking
Ash Removal Procedures
13 MAINTENANCE
Creosote Formation and Removal
Runaway or Chimney Fire
Gasket Replacement
Door Removal
14 WOOD PILE MAINTENANCE
& SERVICE HISTORY
15-16 REPLACEMENTS
Ordering Replacement Parts
Replacement Parts
Accessories
MODEL 1400
& 1400L
25 1/2 in. (65 cm)
27 in. (69 cm)
7 1/2" (19.05 cm)
12 3/4" (32.39 cm)
33 1/4 in. (84cm)
32 in. (81cm)
18 x 18 x 12 in.
(46 x 46 x 31 cm)
(0.05 m
)
2.25 ft
(0.06 m
3
3
3
1000-1800 ft
2
2
2
)
(92-167 m
2
)
60,000 BTU
9 HOURS
250 lbs (113 kg)
145 lbs (66 kg)
MODEL 1401
MODEL 1900
(INSERT)
25 1/2 in. (65 cm)
25 1/2 in. (80 cm)
27 in. (69 cm)
31 1/2 in. (65 cm)
14 1/2 in. (37 cm)
5 1/2" (13.97 cm)
7 1/2" (19.05 cm)
12 3/4" (32.39 cm)
12 3/4" (32.39 cm)
21 1/4 in. (54cm)
33 1/4 in. (84cm)
18 x 18 x 12 in.
22 1/2 x 18 x 12 3/4 in.
(46 x 46 x 31 cm)
(57 x 46 x 32 cm)
)
2.25 ft
(0.06 m
)
3
3
1000-1800 ft
2
(92-167 m
2
)
60,000 BTU
9 HOURS
250 lbs (113 kg)
145 lbs (66 kg)
3
3.0 ft
(0.08 m
)
3
3
1500-2000 ft
2
(139-186 m
2
)
70,000 BTU
12 HOURS
285 lbs (129 kg)
114 lbs (52 kg)
W415-0360 / 11.05.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents