push pin a couple fins to the right or left of the original
hole and re−insert the pin.
           Â
           Â
           Â
           Â
           Â
PUSH PIN
MESH
           Â
SCREEN
           Â
Figure 33. Cleaning Debris from Mesh
THERMOSTAT OPERATION
Though your thermostat may vary somewhat from the
description below, its operation will be similar.
Temperature Setting Levers
Most heat pump thermostats have two temperature
selector levers: one for heating and one for cooling. Set the
levers or dials to the desired temperature setpoints for both
heating and cooling. Avoid frequent temperature
adjustment; turning the unit off and back on before
pressures equalize puts stress on the unit compressor.
Fan Switch
In AUTO or INT (intermittent) mode, the blower operates
only when the thermostat calls for heating or cooling. This
Start−Up and Performance Checklist
Job Name
Job Location
Installer
Unit Model No.
Nameplate Voltage
Rated Load Ampacity
Maximum Fuse or Circuit Breaker
Electrical Connections Tight? -
Indoor Blower RPM
Discharge Pressure
Leak Checked? - Properly Insulated? -
Refrigerant Lines:
Fully Opened? - Caps Tight?
Service Valves:
Voltage With Compressor Operating
506083−01 03/08
9 PINS USED ON −048
AND −060; 6 PINS ALL
OTHERS
Serial No.
Compressor
Indoor Filter clean? -
S.P. Drop Over Indoor (Dry)
Suction Pressure
mode is generally preferred when humidity control is a
priority. The ON or CONT mode provides continuous
indoor blower operation, regardless of whether the
compressor or auxiliary heat are operating. This mode is
required when constant air circulation or filtering is desired.
Set the system switch for heating, cooling or auto
operation. The auto mode allows the heat pump to
automatically switch from heating mode to cooling mode to
maintain predetermined comfort settings. Many heat
pump thermostats are also equipped with an emergency
heat mode which locks out heat pump operation and
provides temporary heat supplied by the auxiliary heat.
Most heat pump thermostats have an amber light which
indicates when the heat pump is operating in the
emergency heat mode.
Temperature indicator displays actual room temperature.
PROGRAMMABLE THERMOSTATS
Your
Lennox
programmable thermostat. These thermostats provide the
added feature of programmable time-of-day setpoints for
both heating and cooling. Refer to the user's information
manual provided with your thermostat for operation
details.
PRESERVICE CHECK
If your system fails to operate, check the following before
calling for service:
S
Make sure all electrical disconnect switches are ON.
S
Make sure the room thermostat temperature selector
AND the system switch are properly set.
S
Replace any blown fuses, or reset circuit breakers.
S
Make sure unit access panels are in place.
S
Make sure air filter is clean.
S
Locate and record unit model number before calling.
Job no.
City
City
Service Technician
Outdoor Fan
Supply Voltage (Unit Off)
Outdoor Coil Entering Air Temp.
Refrigerant Charge Checked?
Outdoor Fan Checked?
-
Calibrated? - Properly Set? - Level? -
Page 20