Service
(continued)
10 . Unplug the gear motor (three connectors) (Fig . 16) .
11 . Remove ground screw connection .
12 . Remove gear motor:
§ Remove M6 allen screw, retainer, spacer and key (Fig . 18 .1) .
§ Remove two M6x90 allen screws (Fig . 18 .2) .
§ Pull gear motor from auger (Fig . 18 .3) .
§ Remove main housing insulation (Fig . 18 .4) .
13 . Remove all traces of petro-gel from auger shaft .
14 . Remove compression nozzle:
§ Loosen hose clamp (Fig . 19 .1) .
§ Remove transport tube (Fig . 19 .2) .
––––––––––––––––––––––––––––––––––––––––––––––––––––
Fig . 17
Fig . 18
Fig . 19
Dispenser and Ice Machine 230 V/50 Hz and 220 V/60 Hz
2
3
1
2
1
2
4
17