Mitsubishi Electric MXZ-2D33VA Service Manual page 426

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-6D122VA COOLING
Indoor units
combination
Unit A
15+20+22+25+35+60
1.03
15+20+22+25+42+42
1.10
15+20+22+25+42+50
1.05
15+20+22+35+35+35
1.13
15+20+22+35+35+42
1.08
15+20+22+35+35+50
1.03
15+20+22+35+42+42
1.04
15+20+25+25+25+25
1.34
15+20+25+25+25+35
1.26
15+20+25+25+25+42
1.20
15+20+25+25+25+50
1.14
15+20+25+25+25+60
1.08
15+20+25+25+35+35
1.18
15+20+25+25+35+42
1.13
15+20+25+25+35+50
1.08
15+20+25+25+35+60
1.02
15+20+25+25+42+42
1.08
5
0
5
5
50
03
15+20+25+25+42+50
1.03
15+20+25+35+35+35
1.11
15+20+25+35+35+42
1.06
15+20+25+35+35+50
1.02
15+20+25+35+42+42
1.02
15+20+35+35+35+35
1.05
15+22+22+22+22+22
1.40
15+22+22+22+22+25
1.38
15+22+22+22+22+35
1.33
15+22+22+22+22+42
1.26
15+22+22+22+22+50
1.20
15+22+22+22+22+60
1.12
15+22+22+22+22+71
1.05
15+22+22+22+25+25
1.37
15+22+22+22+25+35
1.30
15+22+22+22+25+42
1.24
15+22+22+22+25+50
1.17
15+22+22+22+25+60
1.10
15+22+22+22+25+71
1.03
Cooling Capacity (kW)
Unit B
Unit C
Unit D
Unit E
1.38
1.52
1.72
2.41
1.47
1.62
1.84
3.09
1.40
1.54
1.75
2.94
1.51
1.66
2.64
2.64
1.44
1.59
2.53
2.53
1.38
1.52
2.41
2.41
1.39
1.53
2.43
2.91
1.79
2.24
2.24
2.24
1.68
2.10
2.10
2.10
1.61
2.01
2.01
2.01
1.53
1.91
1.91
1.91
1.44
1.79
1.79
1.79
1.57
1.97
1.97
2.75
1.51
1.88
1.88
2.64
1.44
1.79
1.79
2.51
1.36
1.69
1.69
2.37
1.44
1.80
1.80
3.03
38
89
1.38
1.72
1.72
2.89
1.48
1.85
2.59
2.59
1.42
1.77
2.48
2.48
1.36
1.69
2.37
2.37
1.36
1.70
2.39
2.86
1.39
2.44
2.44
2.44
2.06
2.06
2.06
2.06
2.03
2.03
2.03
2.03
1.94
1.94
1.94
1.94
1.85
1.85
1.85
1.85
1.75
1.75
1.75
1.75
1.65
1.65
1.65
1.65
1.54
1.54
1.54
1.54
2.02
2.02
2.02
2.29
1.90
1.90
1.90
2.16
1.81
1.81
1.81
2.06
1.72
1.72
1.72
1.96
1.62
1.62
1.62
1.84
1.52
1.52
1.52
1.72
Unit F
Total
4.14
12.20
( 3.50 -
13.50 )
3.09
12.21
( 3.50 -
13.50 )
3.51
12.19
( 3.50 -
13.50 )
2.64
12.22
( 3.50 -
13.50 )
3.03
12.20
( 3.50 -
13.50 )
3.45
12.20
( 3.50 -
13.50 )
2.91
12.21
( 3.50 -
13.50 )
2.24
12.09
( 3.50 -
13.50 )
2.94
12.18
( 3.50 -
13.50 )
3.37
12.21
( 3.50 -
13.50 )
3.81
12.21
( 3.50 -
13.50 )
4.31
12.20
( 3.50 -
13.50 )
2.75
12.19
( 3.50 -
13.50 )
3.16
12.20
( 3.50 -
13.50 )
3.59
12.20
( 3.50 -
13.50 )
4.07
12.20
( 3.50 -
13.50 )
3.03
12.18
( 3.50 -
13.50 )
3 5
9
3.45
12.19
( 3.50 -
13.50 )
2.59
12.21
( 3.50 -
13.50 )
2.98
12.19
( 3.50 -
13.50 )
3.39
12.20
( 3.50 -
13.50 )
2.86
12.19
( 3.50 -
13.50 )
2.44
12.20
( 3.50 -
13.50 )
2.06
11.70
( 3.50 -
13.10 )
2.30
11.80
( 3.50 -
13.40 )
3.09
12.18
( 3.50 -
13.50 )
3.53
12.19
( 3.50 -
13.50 )
3.99
12.19
( 3.50 -
13.50 )
4.49
12.21
( 3.50 -
13.50 )
4.98
12.19
( 3.50 -
13.50 )
2.29
12.01
( 3.50 -
13.50 )
3.03
12.19
( 3.50 -
13.50 )
3.46
12.19
( 3.50 -
13.50 )
3.91
12.20
( 3.50 -
13.50 )
4.41
12.21
( 3.50 -
13.50 )
4.89
12.20
( 3.50 -
13.50 )
250/362
Outdoor unit
power consumpution
Current (A)
(kW)
3.59
15.78
( 0.92 -
5.32 )
3.60
15.80
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
3.60
15.81
( 0.92 -
5.32 )
3.60
15.79
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
3.63
15.94
( 0.92 -
5.36 )
3.61
15.87
( 0.92 -
5.33 )
3.60
15.83
( 0.92 -
5.32 )
3.60
15.81
( 0.92 -
5.32 )
3.60
15.79
( 0.92 -
5.32 )
3.60
15.82
( 0.92 -
5.32 )
3.60
15.81
( 0.92 -
5.32 )
3.60
15.79
( 0.92 -
5.32 )
3.59
15.77
( 0.92 -
5.32 )
3.60
15.79
( 0.92 -
5.32 )
3 59
5 8
3.59
15.78
( 0.92 -
5.32 )
3.60
15.80
( 0.92 -
5.32 )
3.59
15.79
( 0.92 -
5.32 )
3.59
15.77
( 0.92 -
5.32 )
3.59
15.77
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
3.57
15.69
( 0.95 -
5.49 )
3.60
15.83
( 0.93 -
5.40 )
3.62
15.92
( 0.92 -
5.35 )
3.61
15.87
( 0.92 -
5.33 )
3.60
15.83
( 0.92 -
5.32 )
3.60
15.81
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
3.64
15.97
( 0.92 -
5.37 )
3.62
15.90
( 0.92 -
5.34 )
3.61
15.85
( 0.92 -
5.32 )
3.60
15.82
( 0.92 -
5.32 )
3.60
15.80
( 0.92 -
5.32 )
3.59
15.78
( 0.92 -
5.32 )
Power
factor
(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents