MXZ-3D68VA HEATING
Indoor units
combination
Unit A
18+35+50
1.96
18+35+60
1.87
18+42+42
2.01
18+42+50
1.78
18+42+60
1.71
18+50+50
1.60
20+20+20
2.20
20+20+22
2.11
20+20+25
2.04
1.94
20+20+35
20+20+42
1.66
20+20+50
1.40
1.32
20+20+60
20+22+22
2.00
20+22+25
1.93
20+22+35
1.85
20+22+42
1.61
20+22+50
1.39
20+22+60
1.31
20+25+25
1.87
20+25+35
1.80
20+25+42
1.57
20+25+50
1.35
1.28
20+25+60
20+35+35
1.73
20+35+42
1.52
20+35+50
1.31
20+35+60
1.25
20+42+42
1.35
20+42+50
1.19
20+50+50
1.06
22+22+22
2.87
22+22+25
2.78
22+22+35
2.68
22+22+42
2.37
22+22+50
2.06
22+22+60
1.96
2.70
22+25+25
22+25+35
2.60
22+25+42
2.31
22+25+50
2.01
Heatling capacity (kW)
Unit B
Unit C
Unit D
2.37
4.27
-
2.26
4.47
-
3.29
3.29
-
2.92
3.89
-
2.80
4.09
-
3.50
3.50
-
2.20
2.20
-
2.11
3.17
-
2.04
3.33
-
1.94
3.52
-
1.66
4.08
-
1.40
4.59
-
1.32
4.75
-
3.00
3.00
-
2.90
3.16
-
2.78
3.37
-
2.42
3.96
-
2.08
4.54
-
1.97
4.72
-
3.06
3.06
-
2.94
3.27
-
2.57
3.86
-
2.22
4.43
-
2.10
4.61
-
3.14
3.14
-
2.76
3.72
-
2.39
4.30
-
2.27
4.48
-
3.32
3.32
-
2.92
3.89
-
3.47
3.47
-
2.87
2.87
-
2.78
3.04
-
2.68
3.25
-
2.37
3.87
-
2.06
4.49
-
1.96
4.69
-
2.95
2.95
-
2.84
3.16
-
2.52
3.78
-
2.20
4.39
-
Unit E
Total
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
6.60
-
(2.60-10.00)
7.40
-
(2.60-10.20)
7.40
-
(2.60-10.20)
7.40
-
(2.60-10.20)
7.40
-
(2.60-10.20)
7.40
-
(2.60-10.20)
7.40
-
(2.60-10.20)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.00
-
(2.60-10.40)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
8.60
-
(2.60-10.60)
33/362
Outdoor unit
Current
power consumption(kW)
(A)
2.269
9.96
(4.700-3.445)
2.259
9.92
(3.290-3.435)
2.279
10.01
(4.550-3.455)
2.269
9.96
(3.930-3.445)
2.259
9.92
(1.790-3.435)
2.259
9.92
(2.210-3.435)
1.549
6.80
(0.890-3.085)
1.799
7.90
(0.760-3.215)
1.799
7.90
(0.760-3.215)
1.789
7.86
(0.760-3.205)
1.789
7.86
(1.810-3.205)
1.779
7.81
(3.010-3.195)
1.769
7.77
(4.510-3.185)
2.049
9.00
(0.630-3.345)
2.049
9.00
(0.630-3.345)
2.039
8.95
(0.930-3.335)
2.039
8.95
(1.980-3.335)
2.029
8.91
(3.180-3.325)
2.019
8.87
(4.680-3.315)
2.049
9.00
(0.630-3.345)
2.039
8.95
(1.380-3.335)
2.039
8.95
(2.430-3.335)
2.029
8.91
(3.630-3.325)
2.019
8.87
(5.130-3.315)
2.029
8.91
(2.880-3.325)
2.029
8.91
(3.930-3.325)
2.019
8.87
(5.130-3.315)
2.009
8.82
(2.990-3.305)
2.029
8.91
(4.980-3.325)
2.019
8.87
(3.630-3.315)
2.009
8.82
(1.920-3.305)
2.299
10.10
(0.500-3.475)
2.299
10.10
(0.500-3.475)
2.289
10.05
(1.100-3.465)
2.289
10.05
(2.150-3.465)
2.279
10.01
(3.350-3.455)
2.269
9.96
(4.850-3.445)
2.299
10.10
(0.500-3.475)
2.289
10.05
(1.550-3.465)
2.289
10.05
(2.600-3.465)
2.279
10.01
(3.800-3.455)
Power
factor(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents