Mitsubishi Electric MXZ-2D33VA Service Manual page 357

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-6D122VA COOLING
Indoor units
combination
Unit A
22+35+50
1.97
22+35+60
1.84
22+35+71
1.72
22+42+42
1.99
22+42+50
1.87
22+42+60
1.76
22+42+71
1.66
22+50+50
1.77
22+50+60
1.68
22+50+71
1.60
22+60+60
1.61
22+60+71
1.54
22+71+71
1.48
25+25+25
2.50
25+25+35
2.41
25+25+42
2.42
25+25+50
2.40
5
5 60
0
25+25+60
2.20
25+25+71
2.02
25+35+35
2.34
25+35+42
2.35
25+35+50
2.20
25+35+60
2.04
25+35+71
1.91
25+42+42
2.22
25+42+50
2.09
25+42+60
1.95
25+42+71
1.87
25+50+50
1.98
25+50+60
1.89
25+50+71
1.80
25+60+60
1.81
25+60+71
1.73
25+71+71
1.66
35+35+35
3.20
35+35+42
3.03
Cooling Capacity (kW)
Unit B
Unit C
Unit D
Unit E
3.14
4.49
-
-
2.93
5.03
-
-
2.73
5.55
-
-
3.80
3.80
-
-
3.57
4.25
-
-
3.35
4.79
-
-
3.17
5.36
-
-
4.02
4.02
-
-
3.83
4.59
-
-
3.64
5.16
-
-
4.39
4.39
-
-
4.20
4.97
-
-
4.76
4.76
-
-
2.50
2.50
-
-
2.41
3.38
-
-
2.42
4.06
-
-
2.40
4.80
-
-
0
5 9
2.20
5.29
-
-
2.02
5.75
-
-
3.28
3.28
-
-
3.29
3.95
-
-
3.09
4.41
-
-
2.86
4.90
-
-
2.67
5.42
-
-
3.74
3.74
-
-
3.52
4.19
-
-
3.27
4.68
-
-
3.13
5.30
-
-
3.96
3.96
-
-
3.78
4.53
-
-
3.60
5.11
-
-
4.34
4.34
-
-
4.15
4.92
-
-
4.72
4.72
-
-
3.20
3.20
-
-
3.03
3.64
-
-
Unit F
Total
-
9.60
( 3.50 -
11.20 )
-
9.80
( 3.50 -
11.40 )
-
10.00
( 3.50 -
11.60 )
-
9.59
( 3.50 -
11.20 )
-
9.69
( 3.50 -
11.30 )
-
9.90
( 3.50 -
11.50 )
-
10.19
( 3.50 -
11.80 )
-
9.81
( 3.50 -
11.40 )
-
10.10
( 3.50 -
11.70 )
-
10.40
( 3.50 -
12.00 )
-
10.39
( 3.50 -
12.00 )
-
10.71
( 3.50 -
12.30 )
-
11.00
( 3.50 -
12.60 )
-
7.50
( 3.40 -
9.50 )
-
8.20
( 3.40 -
10.10 )
-
8.90
( 3.50 -
10.50 )
-
9.60
( 3.50 -
10.90 )
9 69
-
9.69
( 3.50 -
11.30 )
-
9.79
( 3.50 -
11.40 )
-
8.90
( 3.50 -
10.60 )
-
9.59
( 3.50 -
11.00 )
-
9.70
( 3.50 -
11.30 )
-
9.80
( 3.50 -
11.40 )
-
10.00
( 3.50 -
11.60 )
-
9.70
( 3.50 -
11.30 )
-
9.80
( 3.50 -
11.40 )
-
9.90
( 3.50 -
11.50 )
-
10.30
( 3.50 -
11.90 )
-
9.90
( 3.50 -
11.50 )
-
10.20
( 3.50 -
11.80 )
-
10.51
( 3.50 -
12.10 )
-
10.49
( 3.50 -
12.10 )
-
10.80
( 3.50 -
12.40 )
-
11.10
( 3.50 -
12.70 )
-
9.60
( 3.50 -
11.20 )
-
9.70
( 3.50 -
11.30 )
181/362
Outdoor unit
power consumpution
Current (A)
(kW)
2.82
12.63
( 0.93 -
4.23 )
2.99
13.41
( 0.93 -
4.36 )
3.11
13.95
( 0.93 -
4.49 )
2.82
12.63
( 0.93 -
4.23 )
2.91
13.04
( 0.93 -
4.29 )
3.05
13.68
( 0.93 -
4.42 )
3.22
14.42
( 0.93 -
4.64 )
2.99
13.41
( 0.93 -
4.36 )
3.17
14.22
( 0.93 -
4.57 )
3.31
14.83
( 0.93 -
4.78 )
3.31
14.83
( 0.93 -
4.78 )
3.39
15.18
( 0.93 -
4.87 )
3.35
15.00
( 0.91 -
4.68 )
1.83
8.19
( 0.93 -
3.22 )
2.14
9.58
( 0.93 -
3.58 )
2.48
11.10
( 0.93 -
3.81 )
2.82
12.63
( 0.93 -
4.05 )
9
3 0
2.91
13.04
( 0.93 -
4.29 )
2.99
13.41
( 0.93 -
4.36 )
2.48
11.10
( 0.93 -
3.87 )
2.82
12.63
( 0.93 -
4.11 )
2.91
13.04
( 0.93 -
4.29 )
2.99
13.41
( 0.93 -
4.36 )
3.11
13.95
( 0.93 -
4.49 )
2.91
13.04
( 0.93 -
4.29 )
2.99
13.41
( 0.93 -
4.36 )
3.05
13.68
( 0.93 -
4.42 )
3.26
14.63
( 0.93 -
4.71 )
3.05
13.68
( 0.93 -
4.42 )
3.22
14.42
( 0.93 -
4.64 )
3.35
15.04
( 0.93 -
4.86 )
3.35
15.04
( 0.93 -
4.86 )
3.37
15.12
( 0.92 -
4.80 )
3.33
14.95
( 0.91 -
4.61 )
2.82
12.63
( 0.93 -
4.23 )
2.91
13.04
( 0.93 -
4.29 )
Power
factor
(%)
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
9
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents