Download Print this page

Yamaha DTP901 Service Manual page 39

Advertisement

XP120SD/XP100SD
QQ
3 7 63 1515 0
3.
Check of installation
• Check that XP100SD can be installed to the clamp
rod smoothly and securely.
• Check that the stereo phone cable can be plugged in
to the [OUTPUT] jack smoothly and securely.
4.
Check of pad function
4-1
Check of level adjustment knob operation
Turn the level adjustment knob clockwise and
counterclockwise while hitting the center of the pad
repeatedly with the same strength and check that output
level changes as the knob is turned. (Fig. C)
• Counterclockwise when seen from the rear side:
Output decreases.
• Clockwise when seen from the rear side:
Output increases.
4-2
Check of pad sensor function
Set the level adjustment knob to the center position.
Hit the center of the and check that the fi rst waveform is
negative. (Refer to the Judgment criteria of waveform)
TE
L 13942296513
Hit repeatedly while changing force and check that
output level changes according to the change of hitting
force.
Level adjustment knob
(レベル調整つまみ)
www
Fig. C (図 C)
.
8
http://www.xiaoyu163.com
Judgment criteria of waveform
+
OK
The first waveform is negative.
(第一波がマイナス側に出る)
Reference waveform
XP120SD
x
ao
u163
y
i
[2V/DIV, 4msec/DIV]
2 9
8
3.
装着確認
• XP100SD はクランプロッドにスムーズにかつ確
実に装着できることを確認します。
• OUTPUT 端子にステレオフォンケーブルのプラ
グがスムーズにかつ確実に装着できることを確
認します。
4.
パッド動作確認
4-1
レベル調整つまみ動作確認
パッド中心を同じ強さで叩きながらレベル調整つ
まみを左右に回転させた時、出力レベルが変化す
ることを確認します。 (図 C)
・裏面から見て反時計回り:出力が小さくなります
・裏面から見て時計回り:出力が大きくなります
4-2
パッドセンサ動作確認
レベル調節つまみを中点にします。
パッド中心を叩き、波形の第一波がマイナスに出
Q Q
ることを確認します。 (波形の判定基準を参照)
3
6 7
1 3
1 5
叩く力に応じて出力レベルが変化することを確認
します。
(波形の判定基準)
+
Time [S]
(参考波形)
XP100SD
co
.
[2V/DIV, 4msec/DIV]
9 4
2 8
0 5
8
2 9
9 4
2 8
NG
Time [S]
The first waveform is positive.
(第一波がプラス側に出る)
m
9 9
9 9

Advertisement

loading

This manual is also suitable for:

Dtp902Dtp900