8.2
Replacing processors
Field Replaceable Unit
(FRU)
Tools: – tool-less
– Removing and installing the processor heat sink:
– Phillips PH2 / (+) No. 2 screw driver
– Removing and installing the processor: tool-less
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
8.2.1
Preliminary steps
Before replacing the processor, perform the following steps:
"Disabling SVOM boot watchdog functionality" on page 54
Ê
"Shutting down the server node" on page 39
Ê
"Removing the server node from the server enclosure" on page 40
Ê
CX2550 M1
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
Processors