Step 10 – Install Filter and Manual Tube
 Screw finger-tight (1) Return Line Filter Head onto hydraulic tank
return port. NOTE: The arrow on filter head should point towards the
tank.
 Wrench-tighten the fitting to 1.5-3.0 Turns Past Finger Tight position.
Consider final orientation position as to not exceed the recommended
Turns Past Finger Tight. Properly assembled fittings total thread
engagement should be 3.5-6 turns.
 CAUTION: Never back off an installed pipe fitting to achieve proper
alignment. Loosening installed pipe fittings will corrupt the seal and
contribute to leakage and failure.
 Screw finger-tight (1) Return Line Filter Canister onto bottom of
return line filter head until gasket makes contact/hand tight. Then,
tighten filter an additional 1/4 turn.
 Remove the manual tube cover from manual tube
 Align holes in manual tube with holes in tow bar
 Secure the manual tube to tow bar using (3) Self-Tapping Screws
 Reattach the manual tube cover onto the manual tube.