11
Driving eccentric of the spreader
.04.04
Requirement
1. When the needle bar is positioned at b.d.c., slot 5 of eccentric 1 should be vertically
above shaft 3.
2. Spreader holder 4 should move a distance of 6 mm.
1
Fig. 11 - 04
Turn eccentric 1 (screws 2) in accordance with requirement 1 or adjust it in accordance
with requirement 2.
5
2
3
62-026
Adjustment
3
4
62-027
11 - 5