Adjustment
13
Reverse-feed lever eccentric
.04.14
Set the maximum stitch length.
Turn the reverse-feed lever 1 (screws 2) according to the rule.
20
Rule
If the needle (at the maximum stitch length setting) is 3 mm above the needle plate from
the top dead centre position, the crank 3 should have reached its front turning point posi-
tion.
Fig. 13 - 14
2
1
2
3