Diagram E
Press UP button once more – Spare. The LCD will display 87.5, which is the software maximum temperature
and is not in use for this product.
Diagram F
Press UP button once more – Fault History
HOO shall be highlighted. If there is a problem with the display PCB Fault code F30 or F31 shall be
highlighted.
Diagram G
To exit the diagnostic mode, press the MENU button. If not terminated manually, diagnostic mode will time out
and go back to default display after 5 minutes.
Note: The door alarms do not operate when the appliance is in diagnostic mode.
5.2

Input / Output Status

To enter input / output status:
Press and hold the MENU button, then press the UP button for 4 seconds. This enters Diagnostic mode.
Press the UP button three times. The current input /output status will be displayed.
If a device is on or a door is open, the respective LCD will be on.
Return to normal operation by pressing the MENU button.
Note: Only the first 6 LCD's are used. The last 5 are not used.
Compressor On
Defrost heater on
FC fan on when
Input/Output Status
door is closed.
Spare
Spare
Fault History
Upper door open
Lower door open
PC Fan on
Low Ambient heater on
Light on