To exit the diagnostic mode, press the MENU key. If not terminated manually, the diagnostic mode
will time out and go back to default display after 5 minutes.
Note: The door alarms do not operate when the appliance is in diagnostic mode.
9
INPUT / OUTPUT STATUS
To enter input / output status:
•
Press and hold the MENU key, then press the UP key for 4 seconds.
Diagnostic mode.
•
Press the UP key three times. The current input /output status will be displayed.
• If a device is on or a door is open, the respective LCD will be on.
• Return to normal operation by pressing the MENU key.
• Note: Only the first 6 LCD's are used. The last 5 are not used.
Compressor on.
Defrost heater
Example.
•
The Compressor is on.
•
The FC fan is on.
•
The PC fan is on.
Note: In I/O mode the illumination of the LCD will turn off if either PC doors are
opened.
9.1
Fault History
The Fault History will indicate the last fault that occurred with the product. However, this will only
be displayed for a periods of 4 days, after which it can only be accessed through a download.
It will also indicate if there are any further faults with the display board. If an icemaker display fault
has occurred, these will be indicated by fault codes F40 or F41 on the LCD Display.
Note: This is fault history and may not necessarily be a current fault.
Input/Output Status
on.
FC fan on when
door is closed.
Upper door open.
Lower drawer open
PC Fan on.
Low Ambient heater on.
Light on.
43
321037