0-0 Help Comments
DTC
FAULT MESSAGE
007 DRIVING AT CUTBACK - POTHOLE STILL
ENGAGED
008 FUNCTIONS LOCKED OUT - SYSTEM
POWERED DOWN
009 DRIVE PREVENTED - ELEVATED ABOVE
DRIVE CUTOUT HEIGHT
2-1 Power-Up
DTC
FAULT MESSAGE
211 POWER CYCLE
212 KEYSWITCH FAULTY
3121165
DESCRIPTION
While stowed, drive speed is reduced since
the control system detected that the pot-
hole protection mechanism failed to
retract.
After 2 hours without activity, the control
system enters a low-power state to pre-
serve battery charge.
The platform is elevated above the cali-
brated cutout height.
DESCRIPTION
This help message is issued at each power
cycle. Displays on the analyzer only.
Both platform and ground modes are
selected simultaneously. Defaults to
ground mode.
– JLG Lift –
SECTION 4 - MACHINE OPERATION
CHECK
• Check for obstructions around the pot-hole protection mechanisms.
• Check that the PHP switches are securely mounted.
Refer problem to a qualified JLG mechanic.
• Normal operation should resume after power is cycled off then back on.
• Check batteries charge, condition, etc.
Refer problem to a qualified JLG mechanic.
• Check that the elevation angle sensor is securely mounted.
Refer problem to a qualified JLG mechanic.
CHECK
Normal operation. No check necessary.
Refer problem to a qualified JLG mechanic.
4-21